York central air conditioner
York YC6 16+ SEER2 Two-Stage Air Conditioner
The York YC6, from York’s LX Series, cools at up to 17 SEER2, with a two-stage scroll compressor on the 2- to 5-ton models and the new R-454B refrigerant. Platinum Air Care installs York air conditioners across London and Southwestern Ontario, each one matched to your furnace and coil.
We install York furnaces and air conditioners, and repair and service most makes already in your home. See the York lineup
At a glance
- Efficiency
- Up to 17 SEER2 / 13.5 EER2
- Compressor
- Two-stage on 2- to 5-ton models
- Sizes
- 1.5 to 5 tons
- Warranties
- 10-year compressor, 10-year parts*
Cooling matched to your home
Two-Stage Central Air, Explained
A single-stage air conditioner has one setting: it runs at full power, shuts off, and starts again at full power. A two-stage air conditioner adds a low stage. On the 2- to 5-ton YC6 models, the scroll compressor runs on low when low is enough and steps up to high when your home needs more cooling.
Each added stage means smaller temperature swings and less energy spent correcting them: better efficiency, lower yearly cooling costs, and a more comfortable home.
The smallest model, the 1.5-ton YC618, is single-stage. From 2 tons up, every YC6 is two-stage.
How each type of air conditioner runs
-
Single-stage
York YC3, single-stage -
Two-stage This page
York YC6, 2 to 5 tons
-
Variable capacity
York YXV, variable capacity
A heat pump is a high-performance air conditioner that also heats your home. See heat pumps
Features
York YC6 Air Conditioner Features
- Up to 17 SEER2 and up to 13.5 EER2 cooling efficiency
- Two-stage scroll compressor on the 2- to 5-ton models (the 1.5-ton model has a single-stage rotary compressor)
- Designed for R-454B, the new refrigerant with a low global warming potential
- High-quality microchannel coil, for consistent, reliable performance
- ECM outdoor fan motor, 1/3 HP, on every size
- Durable steel coil guard and a removable coated-steel fan guard for easy service access
- Automotive-grade powder-coat finish, rated for 1,000 hours of salt-spray testing
- Compact footprint: 29¼ inches square on the 1.5- and 2-ton models
- Runs on a standard, non-communicating thermostat
Benefits
Why a Two-Stage Air Conditioner Like the YC6
-
Lower cost of ownership
At up to 17 SEER2, it costs less to run than an older, less efficient air conditioner.
-
Precise, consistent temperatures
On the 2- to 5-ton models, a low stage and a high stage mean smaller temperature swings than a unit that only runs full on or off.
-
Built for the outdoors
An automotive-grade powder-coat finish, rated for 1,000 hours of salt-spray testing, and a durable steel coil guard that resists corrosion and rust creep.
-
Confidence guaranteed
York’s 10-year compressor and 10-year parts limited warranties* ensure years of dependability.
Technical specification
York YC6 Technical Specifications
- Series
- York LX Series split-system air conditioner
- Efficiency
- Up to 17 SEER2 and up to 13.5 EER2
- Sizes
- 1.5, 2, 3, 4, and 5 tons
- Compressor
- Two-stage scroll (2 to 5 tons); single-stage rotary (1.5 tons)
- Refrigerant
- R-454B
- Coil
- Microchannel
- Outdoor fan
- ECM motor, 1/3 HP; 22- or 26-inch fan
- Thermostat
- Conventional (non-communicating)
- Power
- 208-230 V, single-phase, 60 Hz
- Warranty
- 10-year compressor, 10-year parts limited warranty*
Sizes and dimensions
| Model | Size | Compressor | Fan | Height | Width × depth | Weight |
|---|---|---|---|---|---|---|
| YC618E2S11 | 1.5 tons | Single-stage rotary | 22 in. | 36¼ in. | 29¼ × 29¼ in. | 165 lb |
| YC624E2S11 | 2 tons | Two-stage scroll | 22 in. | 30 in. | 29¼ × 29¼ in. | 150 lb |
| YC636E2S11 | 3 tons | Two-stage scroll | 26 in. | 36¼ in. | 38 × 34¼ in. | 235 lb |
| YC648E2S11 | 4 tons | Two-stage scroll | 26 in. | 39½ in. | 38 × 34¼ in. | 250 lb |
| YC660E2S11 | 5 tons | Two-stage scroll | 26 in. | 42¾ in. | 38 × 34¼ in. | 255 lb |
SEER2 and EER2 are rated for the outdoor unit matched with an indoor coil or air handler. Height is measured to the top of the fan guard; weight is the operating weight.
*From York’s limited warranty: the compressor is covered for 10 years, and parts for 10 years when the unit is registered online within 90 days of installation (or of closing, for a new home), 5 years otherwise. It covers equipment installed in Canada, the United States, and Puerto Rico. Ask us and we’ll help you register it.
York installation
Why Buy Your York From Platinum Air Care
Platinum Air Care has served homes across London and Southwestern Ontario since 1999. A new air conditioner is only as good as the way it goes in.
- One system, sized right. A furnace and air conditioner are one system, so we fit them as a matched pair, sized to your home and your ducts. More on AC replacement and furnace replacement.
- The ducts and the air, too. Because we are an indoor air company as well, we look at the airflow and ducts, not just the box in the basement, and can add whole-home air purification to the same system.
- Installed right. Your York system is installed by licensed HVAC technicians.
- A warranty we back up. When your system is purchased and installed by Platinum Air Care, we don’t just offer the manufacturer warranty, we back it up.
- Service after the install. We repair and service what we install, and emergency service is available: AC repair, furnace repair, and all heating and cooling.
Reviews
What Homeowners Say About Platinum Air Care
Platinum Air Care is rated 4.9 from 2,300+ Google reviews across London and Southwestern Ontario, for air and water treatment, duct cleaning, and heating and cooling.
Complete the system
The York YC6 Pairs Well With
Central air cools through the coil on your furnace and the same ducts, so the furnace, the thermostat, and the air in those ducts are all part of one system.
-
York TM9V Two-Stage Furnace
York’s 96% AFUE gas furnace, with a two-stage burner and a variable-speed ECM fan in a compact, 33-inch-tall cabinet. It is one of the York furnaces we install.
See the York TM9V -
Thermostat Installation
Smart, programmable, and simple thermostats, supplied and professionally installed. The YC6 runs on a standard, non-communicating thermostat.
See thermostats -
Platinum TrueHEPA System
A whole-home HEPA filter system for your furnace that stops 99.97% of particles as small as 0.3 microns.
See the Platinum TrueHEPA
Replacing the furnace at the same time? Along with the TM9V, York’s gas furnaces include the single-stage York TM9E (95% AFUE) and the modulating York YP9C (up to 98% AFUE).
Free quote York central air
Get a Free Quote on a York Air Conditioner
Replacing an old air conditioner, or adding central air for the first time? Call and tell us about your home and the system you have now.
- No cost, no obligation
- Emergency service available
- 4.9 from 2,300+ Google reviews
Request a quote online
Request a Free York Air Conditioner Quote
Share a few details about your home, the system you have now, and how to reach you, and we will call you back.
No cooling right now? Call (519) 686-3595. Emergency service is available.